Imaging equipment model atlas

ImageWare™

Identify Components of Imaging Equipment

Rotate labeled three-dimensional models of imaging systems and select a numbered marker to identify a component and learn what it does. Written profiles and source references provide additional context for each system.

  • Available Now
  • No Account or Installation
  • First load about 90.9 MB
  • Needs WebGL

ImageWare at a Glance

What It Does
A component label and description linked to its location on the model, with references for further reading.
Who It Is For
For students, technologists, and instructors learning to recognize imaging equipment and its components.
Availability
Available Now Runs in a current browser with WebGL. Nothing to install.
How to Launch
Open the full-page program or run it on this page.
  • 32Modeled systems
  • 6Equipment categories
  • 15Written equipment profiles

What You Can Do

  • Browse systems by modality and equipment type.
  • Rotate and zoom models to find labeled components.
  • Read written equipment profiles without loading the three-dimensional atlas.

ImageWare connects equipment appearance with component names and functions. Begin with an equipment category or choose a specific model from the directory. Rotate the model to understand how its parts relate, then use the component key and sources to continue learning. Written equipment profiles are available on the same page.

Where It Fits
For students, technologists, and instructors learning to recognize imaging equipment and its components.

Try This Example

Where are the source, detector, and supporting components on this system?

  1. Choose a system from the equipment directory.
  2. Rotate the model and select a numbered marker.
  3. Compare the label with the component key and open the source tab for more detail.

What You Should See
A component label and description linked to its location on the model, with references for further reading.

Systems

32 Systems Across Six Categories

Select a system to open its model in the atlas workspace.

Stereotactic linear accelerator model in ImageWare

Reading the Markers

Markers identify where an assembly sits on the model. Select a marker or its entry in the component key for a description and sources.

Plain Marker
The point sits on a surface visible from outside the equipment.
Double Ring
The point sits on the housing in front of an enclosed part, such as a tube rotating inside a gantry. It gives that part’s location without claiming to show the part.
Hollow Marker
The point is on the far side of the equipment from the current view.

Try ImageWare

Run the program on this page to follow the example, or open the full-page workspace for more room.

Your data stays in this browser. ImageWare stores nothing and sends nothing to Radiant Medical Physics Specialists. Do not enter patient information, health information, or government identifiers. What Is Stored.

Approximate first load 90.9 megabytes. The models are educational representations. Refer to the manufacturer’s documentation for specifications, operating instructions, and service information. The interactive models require a browser that supports WebGL.

Open Full-Page Program

Screenshots and Instructions

Select a screenshot to view it at full size.

Read the Full Walkthrough
  1. Choose a System. Pick one from the equipment list, or press the forward slash key to search.
  2. Turn the Model. Drag to rotate, scroll or pinch to zoom, and hold Shift to pan. The angle buttons jump to a three-quarter, front, side, or top view.
  3. Select a Marker. Choosing a marker or a key entry names the component. Isolate darkens the view around it, and Center orbits the view around it.
  4. Read the Detail Tabs. Components, Notes, Data, and Sources hold the classification, model notes, key characteristics, and references.

Read how imaging equipment works

Reference

Equipment Profiles

15 written profiles, from computed tomography and radiography to mammography and specialty systems, with how each works, what quality assurance should test, and where protection should focus.

Schematic illustration of computed tomography (ct) equipment (Computer-generated)
Cross-Sectional

Computed Tomography

How It Works
Rotating tube and detector system reconstructs sectional images from many projections.
Quality Assurance Focus
Volume computed tomography dose index/dose-length product review; image uniformity; noise; spatial resolution; low-contrast detectability; geometric and laser alignment.
Protection Focus
Protocol management, scatter around gantry, barrier design, dose alerts, and phantom selection.
Learn More at the Source
Schematic illustration of dental cone-beam ct equipment (Computer-generated)
Dental

Dental Cone-Beam Computed Tomography

How It Works
Rotating cone beam and flat-panel detector create three-dimensional images of oral and maxillofacial structures.
Quality Assurance Focus
Field-of-view accuracy; collimation; geometric alignment; uniformity; noise; spatial resolution; artifacts; radiation output.
Protection Focus
Select clinically appropriate field of view and acquisition settings; apply dental cone-beam computed tomography-specific quality control methods.
Learn More at the Source
Schematic illustration of general radiography equipment (Computer-generated)
Projection

General Radiography

How It Works
Stationary or positioned x-ray tube sends a beam through anatomy to a detector for a projection image.
Quality Assurance Focus
kVp, reproducibility, timer, beam quality, alignment/collimation, automatic exposure control, and detector checks as applicable.
Protection Focus
Limit repeat imaging; collimation and technique charts; primary barrier orientation.
Learn More at the Source
Schematic illustration of mobile radiography equipment (Computer-generated)
Projection

Mobile Radiography

How It Works
Portable x-ray unit captures projection images outside fixed radiographic rooms.
Quality Assurance Focus
Output and beam checks, collimation, locks, battery/mechanical operation, and detector function.
Protection Focus
Control access to the exposure area; consider distance, surroundings, and patient positioning.
Learn More at the Source
Schematic illustration of fluoroscopy / r/f equipment (Computer-generated)
Dynamic Imaging

Fluoroscopy / R/F

How It Works
Real-time x-ray imaging with continuous or pulsed acquisitions and potential spot images.
Quality Assurance Focus
Dose-rate and mode assessment, collimation, image quality, dose indicators, protective equipment, and interlocks.
Protection Focus
Scatter distribution, operator distance, pulsed modes, and high-dose procedure follow-up.
Learn More at the Source
Schematic illustration of c-arm fluoroscopy equipment (Computer-generated)
Mobile Fluoroscopy

C-Arm Fluoroscopy

How It Works
A C-shaped gantry supports x-ray source and detector for surgical or procedural guidance.
Quality Assurance Focus
Geometry, beam restriction, mode output, image quality, mechanical safety, and dose display.
Protection Focus
Beam orientation and operator placement strongly influence scatter exposure.
Learn More at the Source
Schematic illustration of intraoperative cone-beam ct ring gantry equipment (Computer-generated)
Cross-Sectional

Intraoperative Cone-Beam CT (Ring Gantry)

How It Works
Surgical imaging platform capable of two-dimensional fluoroscopic and/or volumetric intraoperative acquisitions.
Quality Assurance Focus
Acquisition modes, image quality, alignment, dose metrics, mechanical, and shielding assessments.
Protection Focus
Procedure-specific room geometry, surgical-team clearance, and mode-dependent scatter.
Learn More at the Source
Dental

Dental Intraoral

How It Works
Small-area x-ray projection used with intraoral receptors or sensors.
Quality Assurance Focus
Tube output, exposure timer, filtration, beam size, alignment, and receptor performance.
Protection Focus
Operator position, beam restriction, technique selection, handheld-device provisions where applicable.
Learn More at the Source
Schematic illustration of panoramic / cephalometric equipment (Computer-generated)
Dental

Panoramic / Cephalometric

How It Works
Rotating panoramic imaging and/or fixed cephalometric projection imaging of craniofacial anatomy.
Quality Assurance Focus
Alignment, field restriction, output, positioning aids, and image quality.
Protection Focus
Patient positioning and appropriate technique selection help avoid retakes.
Learn More at the Source
Schematic illustration of bone densitometer (dxa) equipment (Computer-generated)
Low-Dose Assessment

Dual-Energy x-ray Absorptiometry

How It Works
Dual-energy x-ray measurement used to estimate bone mineral density and related parameters.
Quality Assurance Focus
Calibration/phantom stability, precision, positioning, and quality-control trends.
Protection Focus
Small radiation output does not eliminate the need for appropriate installation and procedures.
Learn More at the Source
Schematic illustration of mammography / tomosynthesis equipment (Computer-generated)
Breast Imaging

Mammography / Tomosynthesis

How It Works
Dedicated low-energy x-ray breast imaging system; tomosynthesis uses multiple projection angles.
Quality Assurance Focus
Modality-specific detector, compression, dose and image-quality tests under applicable accreditation, and Mammography Quality Standards Act requirements.
Protection Focus
Specialized regulatory and physicist qualifications; do not substitute general radiography test protocols.
Learn More at the Source
Schematic illustration of pet/ct or spect/ct equipment (Computer-generated)
Hybrid Imaging

Hybrid Nuclear Medicine and Computed Tomography

How It Works
Combines nuclear medicine emissions imaging and computed tomography-based anatomic localization or attenuation correction.
Quality Assurance Focus
Computed tomography performance plus modality-specific nuclear-medicine calibration and performance checks.
Protection Focus
Both radioactive-material controls and x-ray system radiation protection are relevant.
Learn More at the Source
Industrial/Security

Cabinet x-ray

How It Works
Enclosed irradiation chamber used for inspection or analysis rather than clinical imaging.
Quality Assurance Focus
Interlocks, leakage survey, indicators, enclosure integrity, and operating instructions.
Protection Focus
Applicable requirements differ from medical x-ray devices; assess device classification.
Learn More at the Source
Analytical

X-ray Fluorescence

How It Works
Uses incident x-rays to stimulate characteristic fluorescence for elemental analysis.
Quality Assurance Focus
Tube, detector, shielding, interlocks, and operating geometry checks as applicable.
Protection Focus
Sample access and open-beam configurations can change exposure controls significantly.
Learn More at the Source
Veterinary

Veterinary Radiography

How It Works
Projection x-ray imaging applied to animals using fixed or mobile units.
Quality Assurance Focus
General radiographic performance plus restraint practices, operator training, and examination-space controls.
Protection Focus
Avoid unnecessary personnel in the primary beam; assess protective equipment and alternative restraint.
Learn More at the Source

Profile illustrations are Computer-generated schematic drawings, not photographs of any manufacturer’s product.

Inside ImageWare

What Is Inside

ImageWare showing a rotating computed tomography scanner model with numbered component markers
Recorded in ImageWare with fictional sample data.
  • 01

    Numbered Markers

    Markers sit on each model. A double ring marks an enclosed part behind a housing.

  • 02

    Component Key

    Every component has a classification, a location, and a short description.

  • 03

    Sources

    Each system lists the manufacturer and reference material behind its key.

Know the Limits

The models are educational representations. Refer to the manufacturer’s documentation for specifications, operating instructions, and service information. Do not use ImageWare for service, installation, shielding design, or regulatory determinations.

How Does Imaging Equipment Work? · Ask about ImageWare

Questions About a Program or Resource?

Send a question or suggest a correction. Sign up to hear when programs and resources are updated.