Beyond the x-ray Beam
Radiant Medical Physics Specialists is exploring four new directions in medical physics. See how each field works, read about the software RMPS proposes for it, and help choose what RMPS explores next.
MRI Physics & Safety
The Physics and Why It Matters
Magnetic resonance imaging uses a strong static magnetic field, radiofrequency pulses, and changing gradient fields. The static field produces a net magnetization in hydrogen-rich tissue. Radiofrequency pulses tip that magnetization, and gradients encode the location of the signal used to make an image.
Those same systems create distinct safety considerations. A static field can attract ferromagnetic objects even between scans. Gradients can contribute to acoustic noise and peripheral nerve stimulation, and radiofrequency energy can heat tissue. Medical physicists also help assess scanner performance with test objects called phantoms, using them to investigate problems such as nonuniform images, distortion, or ghosting.
Proposed Program
MRI Safety Walkthrough. A virtual suite would show where access and screening decisions occur. In the full program, learners could follow fictional patient, visitor, and equipment scenarios through the four MR safety zones, identify when information is missing, and review feedback on why a decision belongs at a particular point in the workflow. That gives trainees a way to practice recognizing hazards and escalating uncertainty.
Why RMPS is exploring it. RMPS can apply its experience with room layouts and equipment safety to a modality where controlled access and multiple electromagnetic fields shape how the room is used.
Ultrasound Physics & Quality Assurance
The Physics and Why It Matters
Diagnostic ultrasound sends short pulses of high-frequency sound into the body and uses returning echoes to build an image. Higher frequencies generally improve some aspects of spatial resolution but attenuate more rapidly in tissue, reducing penetration. The focus also affects how well nearby targets can be distinguished laterally at different depths.
Medical physicists and imaging teams can use a tissue-mimicking phantom with known targets to check resolution, sensitivity, and image uniformity. A loss of uniformity may reveal a problem with a probe or imaging channel. On the safety side, the displayed thermal and mechanical indices give operators indicators related to potential bioeffects while they manage acoustic output and scanning time.
Proposed Program
Ultrasound Phantom Lab. Users could change transducer frequency and focal depth, compare targets at several depths, and introduce a simulated element dropout. A future version could save a baseline and ask users to identify whether a change is consistent with settings or points to a possible equipment fault. Students and imaging teams could practice interpreting a QA image before working with a physical phantom.
Why RMPS is exploring it. Ultrasound lets RMPS extend its equipment performance testing work into acoustic imaging. It also provides a practical starting point for a future QuantiRay QA module.
Radioactive Materials Safety
The Physics and Why It Matters
In healthcare, radioactive materials can be used in imaging, therapy, calibration, and research. Unsealed material can spread onto surfaces, so radiation protection teams must consider both external exposure and contamination. A dose-rate survey characterizes radiation levels at a location. A wipe test samples material that can be removed from a surface. Each measurement answers a different question.
This is part of medical health physics, which applies radiation detection, dosimetry, and safety program design to help protect workers, patients, and the public. The work can include instrument selection, contamination monitoring, waste controls, and incident response. In South Carolina, SCDES administers radioactive material licensing and compliance.
Proposed Program
Contamination Survey Simulator. Learners would investigate a fictional radiopharmacy incident by choosing where to sample and comparing dose-rate and wipe-test results. A full scenario could have learners record the instrument, location, and measurement type, then review which findings support a conclusion and which leave uncertainty. This would help learners understand why survey methods are selected and why results need their measurement context.
Why RMPS is exploring it. RMPS can build on its x-ray inspection and survey experience while studying the additional controls needed when radioactive material can remain in a room or move between surfaces.
Nuclear Medicine & Radiopharmaceutical Dosimetry
The Physics and Why It Matters
Nuclear medicine uses radiopharmaceuticals to reveal how a tracer distributes in the body or to deliver radiation to a target. PET detects pairs of annihilation photons, and SPECT detects individual gamma photons from the radionuclide. In radiopharmaceutical therapy, measurements at multiple time points can help estimate how activity changes in tumors and normal organs.
Activity, measured in becquerels, describes how frequently nuclei decay. Absorbed dose, measured in grays, describes the energy deposited per unit mass. The area under a time–activity curve gives the time-integrated activity for a region. To estimate absorbed dose, medical physicists also need a model that accounts for where the emitted radiation deposits energy. Differences in uptake, clearance, and tissue mass help explain why equal administered activities can yield different absorbed doses.
Proposed Program
Radiotracer Kinetics Lab. Users would adjust physical half-life and biological clearance in a fictional two-region model, and a plot would show how those changes affect the activity curves and their areas. A later version could let users change simulated scan times and see how sampling affects the curve fit. The purpose is to connect the measurements a learner sees on a graph to the assumptions behind internal dosimetry.
Why RMPS is exploring it. PET/CT and SPECT/CT are already represented in ShieldScope. This research would extend that equipment-focused work to what happens after administration, opening a path to educational tools on tracer kinetics and dose uncertainty.
What Should RMPS Explore Next?
RMPS will begin with the four research areas above. Tell us which additional topics you’d most like to see become interactive learning tools.