Radiological Health Physics: Analytics Suite
Powered By:
QuantiRay workspace

Home

Health physics calculators, references, and records.

Built for radiation protection work

Run the numbers.
Cite the source.

172 calculators, a searchable technical dictionary, and the reference tables behind them — with the formula and its source kept beside every result. Works fully offline.

Continue

Recent & Saved

RecentLast used
FavoritesBookmarked
Explore

Workspace

177Calculators
306+Indexed entries
OfflineLocal-first
An application by

Radiant Medical Physics Specialists

Radiant Medical Physics Specialists

Results are informational and do not replace professional judgment, calibrated measurements, applicable regulations, or qualified-expert review.

QuantiRay workspace

Calculate

Choose a domain, select a tool, and keep its formula context beside the result.

Calculator
Professional record details
Formula & SourcesTechnical context
Formula Reference

QUICK REFERENCE

1 mSv= 100 mrem
1 Ci= 3.7 × 10¹⁰ Bq
1 Gy= 100 rad
1 R= 2.58 × 10⁻⁴ C/kg
Source Information
Knowledge base

Reference Library

Constants, weighting factors, regulatory values, and the full formula index.

Constants
1 Ci= 3.7 × 10¹⁰ Bq1
1 Bq= 1 dps = 60 dpm
1 Gy= 100 rad = 1 J/kg
1 Sv= 100 rem
1 mSv= 100 mrem
1 R= 2.58 × 10⁻⁴ C/kg1
1 R≈ 8.76 mGy2
W/e3= 33.97 J/C
Natural Log of 2 (ln 2)= 0.693147
Planck Constant (h)= 6.62607015 × 10⁻³⁴ J·s1
Speed of Light (c)= 2.99792458 × 10⁸ m/s1
1 eV= 1.602176634 × 10⁻¹⁹ J1
Electron Rest Energy= 511 keV
1 in= 2.54 cm1
1 ft= 0.3048 m1
1 y4= 365.25 d = 8766 hr
1 Exact value by definition.2 Air kerma delivered in air by 1 R of exposure.3 Mean energy expended in dry air per unit charge of ionization.4 Julian year.
Radiation Weighting Factors (wR)
Photons11
Electrons & Muons1
Protons & Charged Pions2
Alpha ParticlesFission FragmentsHeavy Ions20
Neutrons2.5 – 202
1 All photon energies.2 For neutrons, wR is a continuous function of energy; the ICRP 103 curve spans approximately this range.
Values per ICRP Publication 103. 10 CFR 20 quality factors differ for some radiations (e.g., high-energy protons Q = 10); use the value required by the governing regulation for compliance dose calculations.
Tissue Weighting Factors (wT)
Red Bone MarrowColonLungStomachBreastRemainder Tissues0.12 each
Gonads0.08
BladderEsophagusLiverThyroid0.04 each
Bone SurfaceBrainSalivary GlandsSkin0.01 each
Values per ICRP Publication 103; ΣwT = 1. Note that 10 CFR 20 / equivalent Agreement State regulations still codify the ICRP 26-based wT set for regulatory effective dose equivalent.
Regulatory Dose Limits1
Occupational: Total Effective Dose Equivalent TEDE5 rem/y (50 mSv)
Occupational: Lens Dose Equivalent LDE215 rem/y (150 mSv)
Occupational: Shallow Dose Equivalent, Skin & Extremities SDE350 rem/y (500 mSv)
Occupational: Organ or Tissue DDE + CDE450 rem/y (500 mSv)
Occupational: Minor510% of adult limits
Occupational: Embryo or Fetus60.5 rem / gestation (5 mSv)
Public: Annual Total Effective Dose Equivalent TEDE0.1 rem/y (1 mSv)
Public: Any One Hour2 mrem (0.02 mSv)
1 Per 10 CFR Part 20 and equivalent Agreement State rules.2 Lens dose equivalent (LDE).3 Shallow dose equivalent (SDE) to skin or any extremity.4 Sum of the deep-dose equivalent and committed dose equivalent to any organ or tissue other than the lens of the eye.5 Occupationally exposed individuals under 18 years of age.6 Dose to the embryo/fetus over the entire gestation after a pregnancy has been declared.
Confirm against the current text of the governing regulation (e.g., 10 CFR 20.1201, 20.1207, 20.1208, 20.1301, or the equivalent Agreement State rule) before citing in a compliance context.
Minimum HVL1
kVpDental2Col I3Col II4
301.50.30.3
401.50.40.4
501.50.50.5
511.51.21.3
601.51.31.5
701.51.51.8
712.12.12.5
802.32.32.9
902.52.53.2
1002.72.73.6
1103.03.03.9
1203.23.24.3
1303.53.54.7
1403.83.85.0
1504.14.15.4
1 21 CFR 1020.30(m), Table 1; applies to all diagnostic x-ray systems by type and manufacture date.2 Intraoral dental systems manufactured after Dec 1, 1980.3 Intraoral dental systems manufactured before Dec 1, 1980, and all other systems manufactured before June 10, 2006.4 All other systems manufactured on or after June 10, 2006.
Linear interpolation is permitted for unlisted potentials.
Physical Half-Lives1
RadionuclideSymbolHalf-Life
Rubidium-8282Rb75.45 s
Oxygen-1515O122.24 s
Nitrogen-1313N9.965 min
Carbon-1111C20.364 min
Gallium-6868Ga67.71 min
Fluorine-1818F109.77 min
Technetium-99m99mTc6.0067 hr
Iodine-123123I13.22 hr
Samarium-153153Sm46.28 hr
Yttrium-9090Y64.05 hr
Gold-198198Au2.694 d
Molybdenum-9999Mo65.92 hr
Indium-111111In2.805 d
Thallium-201201Tl3.042 d
Gallium-6767Ga3.262 d
Xenon-133133Xe5.248 d
Lutetium-177177Lu6.644 d
Iodine-131131I8.025 d
Radium-223223Ra11.44 d
Phosphorus-3232P14.27 d
Palladium-103103Pd16.99 d
Strontium-8989Sr50.56 d
Iodine-125125I59.41 d
Iridium-192192Ir73.83 d
Cobalt-5757Co271.7 d
Californium-252252Cf2.645 y
Cobalt-6060Co5.271 y
Hydrogen-33H12.32 y
Strontium-9090Sr28.79 y
Cesium-137137Cs30.08 y
Americium-241241Am432.6 y
Radium-226226Ra1600 y
Carbon-1414C5700 y
1 Common radionuclides encountered in clinical, nuclear medicine, and radioactive materials inspection work; listed shortest to longest.
Occupancy Factors (T)1
OfficesLabsReceptionAttended waiting roomsx-ray control rooms1
Adjacent patient exam & treatment rooms1/2
CorridorsEmployee loungesStaff rest rooms1/5
Corridor doors1/8
Public toiletsUnattended vendingStorageUnattended waiting rooms1/20
Outdoor transient areasStairwaysUnattended elevatorsAttics1/40
1 Suggested values per NCRP Report No. 147, for use when better occupancy data are unavailable; the qualified expert's site-specific values govern the shielding design.
Technical dictionary

Variables & Symbols

Search quantities, symbols, abbreviations, units, and definitions. Entries link directly to the calculators that use them.

Quantities & Units
QuantitySymbolUnitNotes
Absorbed DoseDGy1 Gy = 100 rad
ActivityABq (s⁻¹)1 Ci = 3.7 × 10¹⁰ Bq
Air KermaKGyEntrance value: ESAK; K × area: KAP
Ambient Dose EquivalentH*(10)SvArea monitoring quantity
Annual Limit on IntakeALIBqInternal-dose control (RAM programs)
Backscatter FactorBSFUnitlessEntrance-dose scatter correction
Barrier TransmissionBUnitlessFraction transmitted by a barrier (0–1)
CT Dose IndexCTDImGyCTDIvol = CTDIw / pitch
CT NumberHUUnitless1000 (μ − μw) / μw
CT PitchpUnitlessTable travel ÷ beam width
Decay Constantλs⁻¹λ = ln 2 / T½
Deep Dose (Personal)Hp(10)SvWhole-body individual monitoring
Derived Air ConcentrationDACBq/m³Airborne limit tied to the ALI
Detective Quantum EfficiencyDQEUnitlessSNR²out / SNR²in
Diagnostic Reference LevelDRLUnitlessOptimization benchmark, not a limit
Dose-Length ProductDLPmGy·cmCTDIvol × scan length
Dose-Area or Kerma-Area ProductDAP, KAPGy·cm²Fluoroscopy patient-dose indicator
Effective DiameterDeffcm√(AP × LAT); used for SSDE
Effective DoseESvE = Σ wT·HT
EnergyEJJoule (1 N·m); 1 eV = 1.602176634 × 10⁻¹⁹ J
Equivalent DoseHTSvΣ wR·DT,R; 1 Sv = 100 rem
ExposureXC/kg1 R = 2.58 × 10⁻⁴ C/kg
Exposure / Deviation IndexEI, DIUnitlessDI = 10 log₁₀(EI / EIT)
Eye-Lens Dose (Personal)Hp(3)SvLens-of-eye monitoring
Full Width at Half MaximumFWHMmmProfile width at 50% of peak
Geometric MagnificationMUnitlessM = SID / SOD
Geometry DistancesSID, SOD, OIDcmSID = SOD + OID
Grid RatiorUnitlessStrip height ÷ interspace width
Half-Value & Tenth-Value LayersHVL, TVLmm AlBeam quality & shielding attenuation
Half-LifeT½s – yPhysical Tp, biological Tb, effective Te
Linear Attenuation Coefficientμcm⁻¹μ = ln 2 / HVL
Linear Energy TransferLETkeV/µmEnergy loss per path length
Mass Attenuation Coefficientμ/ρcm²/gMaterial-independent attenuation
Modulation Transfer FunctionMTFUnitlessOutput ÷ input modulation
Occupancy FactorTUnitlessFraction of time an area is occupied (0–1)
Particle and Energy FluenceΦ, Ψm⁻²; J·m⁻²Beam intensity descriptors
Photon EnergyEeV1 eV = 1.602 × 10⁻¹⁹ J
Shallow Dose (Personal)Hp(0.07)SvSkin & extremity monitoring
Signal-to-Noise & Contrast-to-Noise RatiosSNR, CNRUnitlessS̄/σ; |S₁ − S₂|/σ
Size-Specific Dose EstimateSSDEmGyCTDIvol × size factor
Source-to-Skin DistanceSSDcmSSD = SID − patient thickness
Tube Potential & CurrentkVp, mA, mAsUnitlessmAs = mA × s
Use FactorUUnitlessFraction of workload directed at a barrier (0–1)
WorkloadWmA·min/weekWeekly tube loading for shielding design

Operational quantities Hp(d) and H*(10) follow ICRU/ICRP convention; regulatory records under 10 CFR 20 / equivalent state rules use deep-dose equivalent (DDE), shallow-dose equivalent (SDE), and eye-dose equivalent, which these quantities estimate.

History

Select an entry to reload its inputs and recalculate without creating a duplicate history record.

Saved

Bookmarked calculators. Select one to open it.

Personal workspace

Library

Recent tools, favorites, workflows, calculation records, and collections in one place.

Calculator Collections

Quick Actions

Start common calculation, record, comparison, and workflow tasks.

QuantiRay

Library & Settings

Resources, records, preferences, backups, and app diagnostics.

Appearance

Enlarges touch targets and inputs, simplifies the calculator workspace, and keeps the primary result prominent for use beside equipment.

Numerical Presentation

Uncertainty propagation uses independent-input, first-order numerical sensitivity coefficients. Correlated inputs require a covariance-aware method.

Source Framework

The selected context filters source labels and resources; it does not convert one regulatory framework into another.

Export & Backup

Save calculation records or make a restorable copy of locally stored app data.

No stored data

Backups are stored only in the file you download. Importing a backup replaces the app data currently stored in this browser after confirmation.

ApplicationQuantiRay logo with transparent background
OrganizationRadiant Medical Physics Specialists logo with transparent background

QuantiRay provides radiation health physics calculators for field and office use.

Coverage: calculators and conversion tools across inverse square principles, radioactive decay and half-life, radiation protection principles, attenuation and beam quality, computed tomography dosimetry and geometry, exposure techniques and tube performance, structural radiation shielding, radiation dose and kerma quantities, radiation measurement accuracy and uncertainty, fluoroscopic imaging principles, image quality and detector performance, and equipment quality assurance metrics.

Offline Use: This is a single, self-contained HTML file that does not require an internet connection. It can be opened directly in a modern desktop browser; to add it to the Home Screen in Safari, select Share → Add to Home Screen.

History & Saved Calculators: Data are stored locally on this device only.

App Build Formula Library Source Set Record Schema
Calculator Regression Self-TestNot run
Runs a stored known-answer case for every calculator without changing history or saved data.
Use Note: These calculators provide mathematical support only. They do not replace facility-specific protocols, calibrated instrumentation, a qualified expert's shielding design, or the applicable regulatory standard. Verify units and assumptions on each card; regulatory values cited in the Resources tab should be confirmed against the current text of the governing regulation.