Health physics calculators, references, and records.
172 calculators, a searchable technical dictionary, and the reference tables behind them — with the formula and its source kept beside every result. Works fully offline.
Radiant Medical Physics Specialists
Results are informational and do not replace professional judgment, calibrated measurements, applicable regulations, or qualified-expert review.
Choose a domain, select a tool, and keep its formula context beside the result.
Constants, weighting factors, regulatory values, and the full formula index.
| 1 Ci | = 3.7 × 10¹⁰ Bq1 |
| 1 Bq | = 1 dps = 60 dpm |
| 1 Gy | = 100 rad = 1 J/kg |
| 1 Sv | = 100 rem |
| 1 mSv | = 100 mrem |
| 1 R | = 2.58 × 10⁻⁴ C/kg1 |
| 1 R | ≈ 8.76 mGy2 |
| W/e3 | = 33.97 J/C |
| Natural Log of 2 (ln 2) | = 0.693147 |
| Planck Constant (h) | = 6.62607015 × 10⁻³⁴ J·s1 |
| Speed of Light (c) | = 2.99792458 × 10⁸ m/s1 |
| 1 eV | = 1.602176634 × 10⁻¹⁹ J1 |
| Electron Rest Energy | = 511 keV |
| 1 in | = 2.54 cm1 |
| 1 ft | = 0.3048 m1 |
| 1 y4 | = 365.25 d = 8766 hr |
| Photons1 | 1 |
| Electrons & Muons | 1 |
| Protons & Charged Pions | 2 |
| Alpha ParticlesFission FragmentsHeavy Ions | 20 |
| Neutrons | 2.5 – 202 |
| Red Bone MarrowColonLungStomachBreastRemainder Tissues | 0.12 each |
| Gonads | 0.08 |
| BladderEsophagusLiverThyroid | 0.04 each |
| Bone SurfaceBrainSalivary GlandsSkin | 0.01 each |
| Occupational: Total Effective Dose Equivalent TEDE | 5 rem/y (50 mSv) |
| Occupational: Lens Dose Equivalent LDE2 | 15 rem/y (150 mSv) |
| Occupational: Shallow Dose Equivalent, Skin & Extremities SDE3 | 50 rem/y (500 mSv) |
| Occupational: Organ or Tissue DDE + CDE4 | 50 rem/y (500 mSv) |
| Occupational: Minor5 | 10% of adult limits |
| Occupational: Embryo or Fetus6 | 0.5 rem / gestation (5 mSv) |
| Public: Annual Total Effective Dose Equivalent TEDE | 0.1 rem/y (1 mSv) |
| Public: Any One Hour | 2 mrem (0.02 mSv) |
| kVp | Dental2 | Col I3 | Col II4 |
|---|---|---|---|
| 30 | 1.5 | 0.3 | 0.3 |
| 40 | 1.5 | 0.4 | 0.4 |
| 50 | 1.5 | 0.5 | 0.5 |
| 51 | 1.5 | 1.2 | 1.3 |
| 60 | 1.5 | 1.3 | 1.5 |
| 70 | 1.5 | 1.5 | 1.8 |
| 71 | 2.1 | 2.1 | 2.5 |
| 80 | 2.3 | 2.3 | 2.9 |
| 90 | 2.5 | 2.5 | 3.2 |
| 100 | 2.7 | 2.7 | 3.6 |
| 110 | 3.0 | 3.0 | 3.9 |
| 120 | 3.2 | 3.2 | 4.3 |
| 130 | 3.5 | 3.5 | 4.7 |
| 140 | 3.8 | 3.8 | 5.0 |
| 150 | 4.1 | 4.1 | 5.4 |
| Radionuclide | Symbol | Half-Life |
|---|---|---|
| Rubidium-82 | 82Rb | 75.45 s |
| Oxygen-15 | 15O | 122.24 s |
| Nitrogen-13 | 13N | 9.965 min |
| Carbon-11 | 11C | 20.364 min |
| Gallium-68 | 68Ga | 67.71 min |
| Fluorine-18 | 18F | 109.77 min |
| Technetium-99m | 99mTc | 6.0067 hr |
| Iodine-123 | 123I | 13.22 hr |
| Samarium-153 | 153Sm | 46.28 hr |
| Yttrium-90 | 90Y | 64.05 hr |
| Gold-198 | 198Au | 2.694 d |
| Molybdenum-99 | 99Mo | 65.92 hr |
| Indium-111 | 111In | 2.805 d |
| Thallium-201 | 201Tl | 3.042 d |
| Gallium-67 | 67Ga | 3.262 d |
| Xenon-133 | 133Xe | 5.248 d |
| Lutetium-177 | 177Lu | 6.644 d |
| Iodine-131 | 131I | 8.025 d |
| Radium-223 | 223Ra | 11.44 d |
| Phosphorus-32 | 32P | 14.27 d |
| Palladium-103 | 103Pd | 16.99 d |
| Strontium-89 | 89Sr | 50.56 d |
| Iodine-125 | 125I | 59.41 d |
| Iridium-192 | 192Ir | 73.83 d |
| Cobalt-57 | 57Co | 271.7 d |
| Californium-252 | 252Cf | 2.645 y |
| Cobalt-60 | 60Co | 5.271 y |
| Hydrogen-3 | 3H | 12.32 y |
| Strontium-90 | 90Sr | 28.79 y |
| Cesium-137 | 137Cs | 30.08 y |
| Americium-241 | 241Am | 432.6 y |
| Radium-226 | 226Ra | 1600 y |
| Carbon-14 | 14C | 5700 y |
| OfficesLabsReceptionAttended waiting roomsx-ray control rooms | 1 |
| Adjacent patient exam & treatment rooms | 1/2 |
| CorridorsEmployee loungesStaff rest rooms | 1/5 |
| Corridor doors | 1/8 |
| Public toiletsUnattended vendingStorageUnattended waiting rooms | 1/20 |
| Outdoor transient areasStairwaysUnattended elevatorsAttics | 1/40 |
Search quantities, symbols, abbreviations, units, and definitions. Entries link directly to the calculators that use them.
| Quantity | Symbol | Unit | Notes |
|---|---|---|---|
| Absorbed Dose | D | Gy | 1 Gy = 100 rad |
| Activity | A | Bq (s⁻¹) | 1 Ci = 3.7 × 10¹⁰ Bq |
| Air Kerma | K | Gy | Entrance value: ESAK; K × area: KAP |
| Ambient Dose Equivalent | H*(10) | Sv | Area monitoring quantity |
| Annual Limit on Intake | ALI | Bq | Internal-dose control (RAM programs) |
| Backscatter Factor | BSF | Unitless | Entrance-dose scatter correction |
| Barrier Transmission | B | Unitless | Fraction transmitted by a barrier (0–1) |
| CT Dose Index | CTDI | mGy | CTDIvol = CTDIw / pitch |
| CT Number | HU | Unitless | 1000 (μ − μw) / μw |
| CT Pitch | p | Unitless | Table travel ÷ beam width |
| Decay Constant | λ | s⁻¹ | λ = ln 2 / T½ |
| Deep Dose (Personal) | Hp(10) | Sv | Whole-body individual monitoring |
| Derived Air Concentration | DAC | Bq/m³ | Airborne limit tied to the ALI |
| Detective Quantum Efficiency | DQE | Unitless | SNR²out / SNR²in |
| Diagnostic Reference Level | DRL | Unitless | Optimization benchmark, not a limit |
| Dose-Length Product | DLP | mGy·cm | CTDIvol × scan length |
| Dose-Area or Kerma-Area Product | DAP, KAP | Gy·cm² | Fluoroscopy patient-dose indicator |
| Effective Diameter | Deff | cm | √(AP × LAT); used for SSDE |
| Effective Dose | E | Sv | E = Σ wT·HT |
| Energy | E | J | Joule (1 N·m); 1 eV = 1.602176634 × 10⁻¹⁹ J |
| Equivalent Dose | HT | Sv | Σ wR·DT,R; 1 Sv = 100 rem |
| Exposure | X | C/kg | 1 R = 2.58 × 10⁻⁴ C/kg |
| Exposure / Deviation Index | EI, DI | Unitless | DI = 10 log₁₀(EI / EIT) |
| Eye-Lens Dose (Personal) | Hp(3) | Sv | Lens-of-eye monitoring |
| Full Width at Half Maximum | FWHM | mm | Profile width at 50% of peak |
| Geometric Magnification | M | Unitless | M = SID / SOD |
| Geometry Distances | SID, SOD, OID | cm | SID = SOD + OID |
| Grid Ratio | r | Unitless | Strip height ÷ interspace width |
| Half-Value & Tenth-Value Layers | HVL, TVL | mm Al | Beam quality & shielding attenuation |
| Half-Life | T½ | s – y | Physical Tp, biological Tb, effective Te |
| Linear Attenuation Coefficient | μ | cm⁻¹ | μ = ln 2 / HVL |
| Linear Energy Transfer | LET | keV/µm | Energy loss per path length |
| Mass Attenuation Coefficient | μ/ρ | cm²/g | Material-independent attenuation |
| Modulation Transfer Function | MTF | Unitless | Output ÷ input modulation |
| Occupancy Factor | T | Unitless | Fraction of time an area is occupied (0–1) |
| Particle and Energy Fluence | Φ, Ψ | m⁻²; J·m⁻² | Beam intensity descriptors |
| Photon Energy | E | eV | 1 eV = 1.602 × 10⁻¹⁹ J |
| Shallow Dose (Personal) | Hp(0.07) | Sv | Skin & extremity monitoring |
| Signal-to-Noise & Contrast-to-Noise Ratios | SNR, CNR | Unitless | S̄/σ; |S₁ − S₂|/σ |
| Size-Specific Dose Estimate | SSDE | mGy | CTDIvol × size factor |
| Source-to-Skin Distance | SSD | cm | SSD = SID − patient thickness |
| Tube Potential & Current | kVp, mA, mAs | Unitless | mAs = mA × s |
| Use Factor | U | Unitless | Fraction of workload directed at a barrier (0–1) |
| Workload | W | mA·min/week | Weekly tube loading for shielding design |
Operational quantities Hp(d) and H*(10) follow ICRU/ICRP convention; regulatory records under 10 CFR 20 / equivalent state rules use deep-dose equivalent (DDE), shallow-dose equivalent (SDE), and eye-dose equivalent, which these quantities estimate.
Select an entry to reload its inputs and recalculate without creating a duplicate history record.
Bookmarked calculators. Select one to open it.
Recent tools, favorites, workflows, calculation records, and collections in one place.
Start common calculation, record, comparison, and workflow tasks.
Resources, records, preferences, backups, and app diagnostics.
Enlarges touch targets and inputs, simplifies the calculator workspace, and keeps the primary result prominent for use beside equipment.
Uncertainty propagation uses independent-input, first-order numerical sensitivity coefficients. Correlated inputs require a covariance-aware method.
The selected context filters source labels and resources; it does not convert one regulatory framework into another.
Save calculation records or make a restorable copy of locally stored app data.
Backups are stored only in the file you download. Importing a backup replaces the app data currently stored in this browser after confirmation.
QuantiRay provides radiation health physics calculators for field and office use.
Coverage: calculators and conversion tools across inverse square principles, radioactive decay and half-life, radiation protection principles, attenuation and beam quality, computed tomography dosimetry and geometry, exposure techniques and tube performance, structural radiation shielding, radiation dose and kerma quantities, radiation measurement accuracy and uncertainty, fluoroscopic imaging principles, image quality and detector performance, and equipment quality assurance metrics.
Offline Use: This is a single, self-contained HTML file that does not require an internet connection. It can be opened directly in a modern desktop browser; to add it to the Home Screen in Safari, select Share → Add to Home Screen.
History & Saved Calculators: Data are stored locally on this device only.
QuantiRay is the branded name of this radiation health-physics calculator and reference application.
QuantiRay is a mobile-oriented calculation and reference application for radiological health physics, diagnostic imaging physics, radiation protection, equipment quality control, shielding, decay, dosimetry, and related quantitative work.
Select a calculator, enter the requested values and units, then tap Calculate. Review the result together with Formula Reference and Source Information before applying the result.
Use Note: The application provides mathematical and reference support. It does not supersede governing regulations, calibrated instrumentation, manufacturer instructions, facility-specific procedures, or qualified-expert review where required.
The framework filter organizes reference material by the authority or technical context most closely associated with it. These frameworks are not interchangeable.
Always apply the current requirement or method that governs the specific facility, jurisdiction, equipment, and calculation purpose.
Calculators, conversion tools, symbols, references, and your records